Regarding measurement of electric contact


Difference in probe tip shape

H Type

Tip Type:H Plating Material on DUT:Tin(Sn)

Round

Tin(Sn) Plating

H Type Sn

【See also:Dispersion Data(Before-calculating-average】

H Type Sn

※<DUT>Shape : Round/Flat (diameter:Φ16mm height:3mm)

※<Probe>Type : CP20 Tip Material : Carbon tool steel (Aurum plating)

※<Ohm Meter>HIOKI 3560 AC mΩ HITESTER (1mA)

<NOTE>Data can be different by the degree of surface oxidization or of the thickness of the surface plate.
Where the contact areas of DUT and probes are flat, roughness or plating conditions of each surface can easily affect data.

▲PageTop